- Home
- ยป
- Our Products
- »
- Thermal Energy Audit
Thermal Energy Audit
Thermal Energy Audit
Product Brochure
| Type Of Energy | Electrical |
| Usage/Application | Industrial |
| Reason For Audit | New Construction |
| Mode Of Report | Hard Copy, Soft Copy |
| Audit Frequency | Monthly |
| Need Certification | Yes |
These audit aim towards determining efficiencies of generation, distribution & utilization of thermal energies. These are based on Efficient Studies that will be conducted for Boilers, Furnaces, Thermopacks, Ovens and Hot Air and Generators.
Thermal Energy Audit
Product Brochure
| Service Location | Pan India |
| Reason For Audit | New Construction |
| Usage/Application | Industrial |
| Audit Frequency | Yearly |
| Mode Of Report | Soft Copy, Hard Copy |
| Audit Type | Electrical Audit |
Studies are undertaken to determine efficiencies of generation, distribution & Utilisation of thermal energies. Boiler efficiency tests are carried out to determine steam generation to fuel ratio. Condensates coming from coil, jackets, evaporators are collected to arrive at norms for each operation. Exhausts of furnaces, boilers are quantified by analyzing them with our set of equipments. Fixed heating load, start up load & insulation losses are determines. Based on the above results thermal energy balance is struck for reference period of one year. Based on the energy losses identified in the thermal energy balance, energy conservation measures are presented with techno economic analysis. The energy saving areas normally identified are:
Improvement in steam / power generation efficiency, house keeping measures, waste heat recovery, optimal choice of fuel, process optimization etc. Time bound implementation programs are drawn with company manager. We have carried out eighty such audits, mainly in process industries in India. We have achieved savings ranging from 4 to 30 % in the thermal energy expenses of our clients.
We have done detailed process design engineering for the following products. Dry Ice, Sodium Sulphate, Dilute Sulphuric Acid from 98% acid, Multiple effect evaporation systems for caustic solution (upto seven effects) & H-acid & Continuous Calcinations.
2) EPC FOR UTILITIESFor new or expansion projects, we provide engineering procurement & commissioning assistance for utilities including steam generators, turbines, hot oil units, direct fired equipments, compressors, piping etc. We have executed such projects in textile, basic chemicals, tyres, paper, chemicals etc
Commercial Building Energy Audits
Product Brochure
| Type Of Load | Lighting |
| Reason For Audit | New Construction |
| Services Include | Lighting Systems, Power Systems, Building Envelope |
| Power Rating | >22 kVA |
| Building Type | Ground Floor |
| Construction Area | 1000 to 1500 Square Feet |
| Need Certification | Yes |
| Usage/Application | Commercial |
The salient features are as below:
- Study of steam systems, hot oil systems & hot air generators
- General energy saving potential areas :improvement in steam / power generation efficiency, house keeping measures, waste heat recovery, optimal choice of fuel, process optimization etc.
- Boiler conversion from furnace oil to renewable fuel.
Electrical Thermal Energy Audit
Product Brochure
| Type Of Energy | Electrical |
| Usage/Application | Industrial |
| Reason For Audit | New Construction |
| Audit Type | Electrical Audit |
| Mode Of Report | Soft Copy, Hard Copy |
| Audit Frequency | One Time Requirement |
| Need Certification | Yes |
Areas Cover in Thermal Energy Audit:
- Boilers
- Steam Distribution
- Insulation
- Ventilation System
- Hydraulic Systems
- Heat Exchangers
- Furnaces, Boilers, Ovens
- Steam Traps
Thermal Energy Audit For Industrial
Product Brochure
| Type Of Energy | Electrical |
| Usage/Application | Industrial |
| Reason For Audit | New Construction |
| Mode Of Report | Soft Copy, Hard Copy |
| Audit Frequency | Yearly |
These Thermal Energy Audit aim towards determining efficiencies of generation, distribution & utilization of thermal energies. These are based on Efficient Studies that will be conducted for Boilers, Furnaces, Thermopacks, Ovens and Hot Air and Generators.
Other Details:
- Durable
- Highly reliable
- Efficient
New Plant Thermal Energy Audit
Product Brochure
| Type Of Energy | Electrical |
| Usage/Application | Industrial |
| Reason For Audit | New Construction |
| Audit Type | Electrical Audit |
| Mode Of Report | Soft Copy, Hard Copy |
| Audit Frequency | One Time Requirement |
| Need Certification | Yes |
These audit aim towards determining efficiencies of generation, distribution & utilization of thermal energies. These are based on Efficient Studies that will be conducted for Boilers, Furnaces, Thermopacks, Ovens and Hot Air and Generators.
The salient features are as below
- Study of steam systems, hot oil systems, hot air generators
- General energy saving potential areas improvement in steam / power generation efficiency, house keeping measures, waste heat recovery, optimal choice of fuel, process optimization etc.
- Boiler conversion from furnace oil to renewable fuel.
Thermal Audit Service
Product Brochure
| Service Location | On Site |
| Type Of Service Provider | Thermal Audit Service |
| Usage/Application | Industrial |
| MOde | Ofline |
| Application Area | Industrial |
Following are some of the details of the service offered by us:
- Temperature: 58.0 Deg C
- temperature rise is above 20.0 Deg C
- Suitable for blue wire strand and wire for a bad connection
Advantages of Thermography:
- Keeps user out of danger when scanning electrical systems
- Minimizes unscheduled downtime by detecting the faults before failure
- Prolongs machinery life
- Saves energy
- Monitors tank and vessel levels from far distance
- Infrared region appears between 0.8 microns to 1000 microns wavelength
- Thermal imaging cameras detect radiation in the infrared range of the electromagnetic spectrum (roughly 900-14,000 nanometers or 0.9-14 um)
- Produces image of that radiation
- Measures temperature on defective components
- The resistance or molecular friction produced within these problem areas is visible in the infrared spectrum
- Can identify bearing problems quickly and easily
Following are some of the details of the service offered by us:
- Temperature: 58.0 Deg C
- temperature rise is above 20.0 Deg C
- Suitable for blue wire strand and wire for a bad connection
Advantages of Thermography:
- Keeps user out of danger when scanning electrical systems
- Minimizes unscheduled downtime by detecting the faults before failure
- Prolongs machinery life
- Saves energy
- Monitors tank and vessel levels from far distance
- Infrared region appears between 0.8 microns to 1000 microns wavelength
- Thermal imaging cameras detect radiation in the infrared range of the electromagnetic spectrum (roughly 900-14,000 nanometers or 0.9-14 um)
- Produces image of that radiation
- Measures temperature on defective components
- The resistance or molecular friction produced within these problem areas is visible in the infrared spectrum
- Can identify bearing problems quickly and easily
Following are some of the details of the service offered by us:
- Temperature: 58.0 Deg C
- temperature rise is above 20.0 Deg C
- Suitable for blue wire strand and wire for a bad connection
Advantages of Thermography:
- Keeps user out of danger when scanning electrical systems
- Minimizes unscheduled downtime by detecting the faults before failure
- Prolongs machinery life
- Saves energy
- Monitors tank and vessel levels from far distance
- Infrared region appears between 0.8 microns to 1000 microns wavelength
- Thermal imaging cameras detect radiation in the infrared range of the electromagnetic spectrum (roughly 900-14,000 nanometers or 0.9-14 um)
- Produces image of that radiation
- Measures temperature on defective components
- The resistance or molecular friction produced within these problem areas is visible in the infrared spectrum
- Can identify bearing problems quickly and easily